Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Cancer Res Clin Oncol ; 150(4): 200, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627285

RESUMO

PURPOSE: Isolated locoregional recurrence of breast cancer (ILRR) and contralateral breast cancer (CBC) affect up to 20% of all breast cancer (BC) patients in the first 20 years after primary diagnosis. Treatment options comprise surgical interventions and further systemic therapies depending on the histological subtype. Patients with hereditary breast or ovarian cancer (HBOC) undergo MRI, mammography, and ultrasound in the aftercare of BC, while non-HBOC (nHBOC) patients do not regularly receive MRI. Since early detection is crucial for morbidity and mortality, the evaluation and constant improvement of imaging methods of the breast is necessary. METHODS: We retrospectively analyzed the data of 1499 former BC patients that received imaging of the breast at a tertiary-care university hospital between 2015 and 2020. The analysis comprised various patient characteristics, such as breast density, age, tumor size and subtype, and their influence on BC detection rates by the different imaging methods. RESULTS: Within the patient sample, 176 individuals (11.7% of former BC patients) were diagnosed with either ILRR or CBC. CBC was observed in 32.4% of patients, while both ILRR and secondary breast cancer occurred in 20.5% and 23.9% of all patients. Sensitivity of MRI, mammography, and ultrasound for recurrent malignancy was 97.9%, 66.3%, and 67.8%, respectively. ILRR and CBC detection rates were similar for patients with and without HBOC history. Lower breast density and larger tumor size increased the detection rates of all imaging modalities. CONCLUSION: In breast cancer survivors, MRI might improve the early detection of ILRR and CBC in both HBOC and nHBOC patients.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/patologia , Estudos Retrospectivos , Recidiva Local de Neoplasia/patologia , Mamografia
2.
Radiography (Lond) ; 29(1): 44-49, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36274316

RESUMO

INTRODUCTION: This study investigated the image quality of a new quantum iterative reconstruction algorithm (QIR) for high resolution photon-counting CT of the hip. METHODS: Using a first-generation photon-counting CT scanner, five cadaveric specimens were examined with ultra-high-resolution protocols matched for radiation dose. Images were post-processed with a sharp convolution kernel and five different strength levels of iterative reconstruction (QIR 0 - QIR 4). Subjective image quality was rated independently by three radiologists on a five-point scale. Intraclass correlation coefficients (ICC) were computed for assessing interrater agreement. Objective image quality was evaluated by means of contrast-to-noise-ratios (CNR) in bone and muscle tissue. RESULTS: For osseous tissue, subjective image quality was rated best for QIR 2 reformatting (median 5 [interquartile range 5-5]). Contrarily, for soft tissue, QIR 4 received the highest ratings among compared strength levels (3 [3-4]). Both ICCbone (0.805; 95% confidence interval 0.711-0.877; p < 0.001) and ICCmuscle (0.885; 0.824-0.929; p < 0.001) suggested good interrater agreement. CNR in bone and muscle tissue increased with ascending strength levels of iterative reconstruction with the highest results recorded for QIR 4 (CNRbone 29.43 ± 2.61; CNRmuscle 8.09 ± 0.77) and lowest results without QIR (CNRbone 3.90 ± 0.29; CNRmuscle 1.07 ± 0.07) (all p < 0.001). CONCLUSION: Reconstructing photon-counting CT data with an intermediate QIR strength level appears optimal for assessment of osseous tissue, whereas soft tissue analysis benefitted from applying the highest strength level available. IMPLICATIONS FOR PRACTICE: Quantum iterative reconstruction technique can enhance image quality by significantly reducing noise and improving CNR in ultra-high resolution CT imaging of the hip.


Assuntos
Osso e Ossos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
3.
Radiography (Lond) ; 29(1): 19-27, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36209641

RESUMO

INTRODUCTION: The aim of this study was to evaluate the influence of a noise optimized virtual monoenergetic reconstruction algorithm (VMI+) on the image quality and assessability of dual energy (DE) computed tomography angiography (CTA) of the lower extremity runoff. METHODS: A total of 118 lower extremity runoff CTA performed on a 3rd generation DE-CT scanner in 109 patients (54 females; 75.6 ± 9.5 years) were included in this retrospective study. Axial image stacks were reconstructed with a standard 120 kV setting and VMI+ of different keV levels. Objective image quality criteria (contrast attenuation, signal-to-noise [SNR] and contrast-to-noise ratio [CNR]) were measured. Two radiologists evaluated subjective image quality regarding intraluminal attenuation and image noise using a 5-point Likert scale. Diagnostic accuracy for significant stenosis (>75%) and vessel occlusion was assessed for 120 kV and 50 keV VMI+ images rated by two radiologists. In all patients, a digital subtraction angiography (DSA) rated by on board-certified radiologist served as the standard of reference. RESULTS: Intraluminal attenuation was highest in 40/50 keV VMI+ while SNR were similar to 120 kV images. In subjective assessment, intraluminal contrast of 50 keV images was deemed superior compared to 120 kV despite higher image noise. Sensitivity, specificity, and accuracy for detection of a vessel occlusion were similar in 50 keV VMI+ compared to 120 kV (70%/92%/84%; 70%/91%/83%; p < 0.001) but 13 of 118 (11%) lower leg runoffs were only assessable with 50 keV VMI+. CONCLUSION: VMI+ reconstructions improve assessability of DE-CTA by increased luminal attenuation with consistent image noise, also allowing the evaluation of lower leg arterial segments inassessable with standard reconstructions. IMPLICATIONS FOR PRACTICE: Providing higher intraluminal attenuation and similar image noise compared with conventional reconstructions, 50 keV VMI+ may be appropriate for routine evaluation of DE-CTA.


Assuntos
Angiografia por Tomografia Computadorizada , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Feminino , Humanos , Angiografia por Tomografia Computadorizada/métodos , Perna (Membro)/diagnóstico por imagem , Razão Sinal-Ruído , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Extremidade Inferior/diagnóstico por imagem
4.
Eur J Radiol ; 139: 109653, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33838429

RESUMO

PURPOSE: This study aimed to assess the feasibility of Self-gated Non-Contrast-Enhanced Functional Lung (SENCEFUL) MRI for detection of pulmonary perfusion deficits in patients with cystic fibrosis. METHODS: Twenty patients with cystic fibrosis and 20 matched healthy controls underwent SENCEFUL-MRI at 1.5 T with reconstruction of perfusion and perfusion phase maps (i.e. comparable to pulse wave delays). Four blinded readers rated both types of maps separately followed by simultaneous assessment thereof. Perfusion phase data was plotted in histograms and a Peak-to-Offset ratio was calculated for comparison to subjective scoring and correlation (Spearman) to lung function parameters. Sensitivity, specificity and positive and negative predictive values were calculated for subjective scoring and Peak-to-Offset ratios. Intraclass correlation (ICC) was used to assess the interrater agreement. RESULTS: Readers attributed pathological ratings 2.2-3.5 times more frequently to the CF-group. The sensitivity with regard to a correct assignment to CF was similar between ratings (perfusion only vs. perfusions phase only vs. simultaneous assessment: 0.54-0.56), while specificity increased from 0.75 to 0.85 for simultaneous assessment. ICC was 0.77-0.84 for subjective scoring. ROC-analysis of Peak-to-Offset ratios on a mean per-subject basis revealed a sensitivity of 0.75 and specificity of 0.85 (PPV 0.83, NPV 0.77). Functional pulmonary parameters indicative of bronchial obstruction and Peak-to-Offset ratios showed positive correlation (FEV1: 0.77; FEF75: 0.76). CONCLUSIONS: SENCEFUL-MRI bears the potential for monitoring CF including disease-associated patterns of altered pulmonary perfusion. The proposed Peak-to-Offset ratio derived from pulmonary perfusion phase measurements could represent an objective future marker for perfusion impairment.


Assuntos
Obstrução das Vias Respiratórias , Fibrose Cística , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão
5.
Chirurg ; 91(5): 405-412, 2020 May.
Artigo em Alemão | MEDLINE | ID: mdl-31915871

RESUMO

During the last two decades a neoadjuvant treatment concept has been established for an increasing number of malignant tumors of the gastrointestinal tract; however, these concepts are still subject to a constant change concerning the indications and type of treatment. A prime example for this is rectal cancer. The rate of local recurrence in particular was significantly reduced by neoadjuvant therapy but until now it has not been possible to validly show an improvement in overall or disease-free survival. At the beginning of the millennium it was recommended to treat every rectal carcinoma in UICC stages II and III with neoadjuvant therapy, independent of the height localization. In the meantime this has increasingly been relativized and only locally advanced tumors of the middle and lower thirds of the rectum should be pretreated, whereas tumors of the upper third of the rectum should basically be treated in the same way as colon cancer. It is to be expected that there will be further differentiation concerning the indications in this context in the future mainly based on a preoperative magnetic resonance imaging (MRI) examination. At the same time, initial studies for colon cancer show that neoadjuvant chemotherapy can be beneficial and that an optimized computed tomography (CT) scan can be a worthwhile tool with respect to pretherapeutic stratification of patients.


Assuntos
Neoplasias do Colo , Neoplasias Retais , Quimiorradioterapia , Humanos , Terapia Neoadjuvante , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Seleção de Pacientes , Resultado do Tratamento
6.
BMC Cardiovasc Disord ; 16(1): 205, 2016 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-27793097

RESUMO

BACKGROUND: Fabry disease is characterized by a progressive deposition of sphingolipids in different organ systems, whereby cardiac involvement leads to death. We hypothesize that lysosomal storage of sphingolipids in the heart as occurring in Fabry disease does not reflect in higher cardiac lipid concentrations detectable by 1H magnetic resonance spectroscopy (MRS) at 3 Tesla. METHODS: Myocardial lipid content was quantified in vivo by 1H-MRS in 30 patients (12 male, 18 female; 18 patients treated with enzyme replacement therapy) with genetically proven Fabry disease and in 30 healthy controls. The study protocol combined 1H-MRS with cardiac cine imaging and LGE MRI in a single examination. RESULTS: Myocardial lipid content was not significantly elevated in Fabry disease (p = 0.225). Left ventricular (LV) mass was significantly higher in patients suffering from Fabry disease compared to controls (p = 0.019). Comparison of patients without signs of myocardial fibrosis in MRI (LGE negative; n = 12) to patients with signs of fibrosis (LGE positive; n = 18) revealed similar myocardial lipid content in both groups (p > 0.05), while the latter showed a trend towards elevated LV mass (p = 0.076). CONCLUSIONS: This study demonstrates the potential of lipid metabolic investigation embedded in a comprehensive examination of cardiac morphology and function in Fabry disease. There was no evidence that lysosomal storage of sphingolipids influences cardiac lipid content as measured by 1H-MRS. Finally, the authors share the opinion that a comprehensive cardiac examination including three subsections (LGE; 1H-MRS; T1 mapping), could hold the highest potential for the final assessment of early and late myocardial changes in Fabry disease.


Assuntos
Cardiomiopatias/metabolismo , Doença de Fabry/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Miocárdio/metabolismo , Esfingolipídeos/metabolismo , Adolescente , Adulto , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/etiologia , Doença de Fabry/complicações , Doença de Fabry/metabolismo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Fatores de Tempo , Função Ventricular Esquerda , Adulto Jovem
7.
Rofo ; 187(11): 1016-21, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26230138

RESUMO

PURPOSE: The role of myocardial triglyceride (mTG) content in the aging human heart is not entirely understood. The aim of this study was to measure concentrations of mTG content from healthy volunteers and to determine the association between age, mTG content and systolic heart function. Furthermore, the technical stability of the (1)H-magnetic resonance spectroscopy ((1)H-MRS) and the reliability of peak evaluation at 3 T were evaluated. MATERIALS AND METHODS: The total study population of 47 healthy volunteers was divided into 4 age classes, according to the age of the subjects (1(st) cohort 20 - 29 years (yrs.), n = 20; 2(nd) cohort 30 - 39 yrs., n = 10; 3(rd) cohort 40 - 49 yrs., n = 9; 4(th) cohort 50 - 60 yrs., n = 8). Cardiac MRI and double triggered (1)H-MRS of the myocardium were consecutively performed using a 3 T scanner. Each participant underwent spectroscopic measurements twice in the same investigation. RESULTS: mTG content increases with age. The correlation of age and mTG is minimal (r = 0.48; p < 0.001). The following age-averaged mTG content values expressed as % of mTG signal compared to the water signal were determined for each cohort: 1(st) cohort 0.25 % (±â€Š0.17); 2(nd) cohort 0.48 % (±â€Š0.30); 3(rd) cohort 0.48 % (±â€Š0.18); 4(th) cohort 0.77 % (±â€Š0.70). There was no significant correlation (r = 0.04; p = n.s.) between LV mass and mTG content in healthy volunteers. Within our cohorts, no effects of age or mTG content on systolic heart function were seen (r = - 0.01; p = n.s.). The intraclass correlation coefficient of spectroscopic measurements was high (r = 0.965; p < 0.001). CONCLUSION: Myocardial TG content increases with age. The normal age-dependent concentration ranges of myocardial lipid metabolites reported in this study may be helpful for the correction of acquired (1)H-MRS data in patients when evaluating metabolic and cardiovascular diseases in future magnetic resonance spectroscopy studies.


Assuntos
Envelhecimento/fisiologia , Miocárdio/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/métodos , Triglicerídeos/metabolismo , Adulto , Estudos de Coortes , Frequência Cardíaca/fisiologia , Septos Cardíacos/metabolismo , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Volume Sistólico/fisiologia , Adulto Jovem
8.
Rofo ; 186(2): 136-41, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23996622

RESUMO

PURPOSE: To evaluate the feasibility, frequency of use, types of intervention and labor costs of a formal round-the-clock interventional radiology on-call service. MATERIALS AND METHODS: In 11/2011 a formal and permanent out-of-hour interventional radiology rota in addition to the general radiology out-of-hour rota (OOHR) was established. We retrospectively screened the interventional radiology database for procedures completed outside regular working hours, reviewed all interventions and manually selected cases in which the on-call interventionist was called in from home. We determined the type, frequency of use and costs (€/year and procedure) of this service between 1/2012 and 12/2012. The referring physicians' (sub-) specialties were evaluated. RESULTS: During the 12-month period, the on-call interventionists (n = 3) performed 92 procedures OOH. The procedures included angiography and hemorrhage control (n = 36, 39.1 %), angiography and intervention for acute limb ischemia (n = 25, 27.2 %), percutaneous biliary drainage (PTCD) (n = 10, 10.9 %), angiography for non-occlusive ischemia (n = 7, 7.6 %), and other (n = 14, 15.3 %). The total labor costs for the OOHR were €â€Š42,312.21 (€â€Š32,982.60 lump sum for stand-by, €â€Šâ€Š9,329.61 for hours spent on procedures). The labor costs per procedure totaled €â€Š459.92. The referring physicians' specialties were general/visceral (n = 25), vascular surgery (n = 24), internal medicine (n = 21), cardiac/thoracic vascular (n = 9), trauma surgery (n = 5), urology (n = 5), and anesthesiology (n = 3). CONCLUSION: A formal interventional OOHR is practicable in a university hospital setting. Most procedures were requested by general, vascular, and thoracic surgery as well as internal medicine with a focus on hemorrhage control, treatment of acute limb ischemia, and PTCD. The overall labor costs for the OOHR appear moderate. KEY POINTS: • In a university setting an OOHR for IR is feasible.• Labor costs per procedure appear moderate.• Hemorrhage control and treatment of limb ischemia were the most frequent procedures. Citation Format: • Goltz JP, Janssen H, Petritsch B et al. Launching a Permanent Out-of-Hour Interventional Radiology Service: Single-Center Experience from a German University Hospital. Fortschr Röntgenstr 2014; 186: 136 - 141.


Assuntos
Centros Médicos Acadêmicos/economia , Plantão Médico/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Serviço Hospitalar de Radiologia/economia , Radiologia Intervencionista/economia , Centros Médicos Acadêmicos/estatística & dados numéricos , Plantão Médico/estatística & dados numéricos , União Europeia , Alemanha , Serviço Hospitalar de Radiologia/estatística & dados numéricos , Radiologia Intervencionista/estatística & dados numéricos , Encaminhamento e Consulta
9.
Rofo ; 184(11): 1020-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22893488

RESUMO

PURPOSE: In Fabry disease (FD), a progressive deposition of sphingolipids is reported in different organs. The present study applied 1H magnetic resonance spectroscopy (MRS) to investigate the myocardial lipid content in FD. MATERIALS AND METHODS: In patients (PTS, n = 15) with genetically proven FD, 1H MRS of the heart was acquired in the same examination as routine cardiac cine and late enhancement MR imaging. Healthy volunteers (n = 11) without history of cardiac disease served as control (CTL). Myocardial triglycerides in vivo were quantified in 1H MRS. Left ventricular (LV) ejection fraction (EF) and late enhancement were assessed for the determination of LV systolic function, and onset or absence of myocardial fibrosis. RESULTS: All 1H MRS revealed resonances for intramyocardial triglycerides. Clinical parameters, e.g. EF (PTS 64 ± 2 % vs. CTL 61 ± 1 %) were similar in PTS and CTL or showed a non-significant trend (LV mass). Apart from a single patient with elevated myocardial triglycerides, no significant impact of Fabry disease on the triglyceride/water resonance ratio (PTS 0.47 ± 0.11 vs. CTL 0.52 ± 0.11 %) was observed in our patient cohort. CONCLUSION: A comprehensive cardiac evaluation of morphology, function as well as metabolism in Fabry PTS with suspected cardiac involvement is feasible in a single examination. No significant effect of myocardial triglyceride deposition could be observed in patients. The remarkably high myocardial triglyceride content in one patient with advanced FD warrants further studies in PTS with an extended history of the disease.


Assuntos
Doença de Fabry/diagnóstico , Doença de Fabry/fisiopatologia , Espectroscopia de Ressonância Magnética/métodos , Miocárdio/metabolismo , Triglicerídeos/metabolismo , Adolescente , Adulto , Idoso , Feminino , Glicoesfingolipídeos/metabolismo , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Triexosilceramidas/metabolismo , Adulto Jovem
10.
Br J Radiol ; 85(1019): e966-72, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22674705

RESUMO

OBJECTIVES: To evaluate the technical success, clinical outcome and safety of percutaneously placed totally implantable venous power ports (TIVPPs) approved for high-pressure injections, and to analyse their value for arterial phase CT scans. METHODS: Retrospectively, we identified 204 patients who underwent TIVPP implantation in the forearm (n=152) or chest (n=52) between November 2009 and May 2011. Implantation via an upper arm (forearm port, FP) or subclavian vein (chest port, CP) was performed under sonographic and fluoroscopic guidance. Complications were evaluated following the standards of the Society of Interventional Radiology. Power injections via TIVPPs were analysed, focusing on adequate functioning and catheter's tip location after injection. Feasibility of automatic bolus triggering, peak injection pressure and arterial phase aortic enhancement were evaluated and compared with 50 patients who had had power injections via classic peripheral cannulas. RESULTS: Technical success was 100%. Procedure-related complications were not observed. Catheter-related thrombosis was diagnosed in 15 of 152 FPs (9.9%, 0.02/100 catheter days) and in 1 of 52 CPs (1.9%, 0.002/100 catheter days) (p<0.05). Infectious complications were diagnosed in 9 of 152 FPs (5.9%, 0.014/100 catheter days) and in 2 of 52 CPs (3.8%, 0.003/100 catheter days) (p>0.05). Arterial bolus triggering succeeded in all attempts; the mean injection pressure was 213.8 psi. Aortic enhancement did not significantly differ between injections via cannulas and TIVPPs (p>0.05). CONCLUSIONS: TIVPPs can be implanted with high technical success rates, and are associated with low rates of complications if implanted with sonographic and fluoroscopic guidance. Power injections via TIVPPs are safe and result in satisfying arterial contrast. Conventional ports should be replaced by TIVPPs.


Assuntos
Cateteres Venosos Centrais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateteres Venosos Centrais/efeitos adversos , Meios de Contraste/administração & dosagem , Feminino , Antebraço , Humanos , Injeções Intravenosas/instrumentação , Injeções Intravenosas/métodos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Tórax , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
11.
Clin Radiol ; 67(11): 1101-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22583951

RESUMO

This article focuses on radiological imaging of complications after interventional percutaneous insertion of totally implantable venous access ports (TIVAPs) which were placed in the forearm. Thus far most reviews have dealt with pectorally-placed TIVAPs. Compared with the pectoral approach, implantation in the forearm has been associated with certain complications owing to a longer route of the port catheter within a smaller vein, and owing to the route across the elbow joint, resulting in higher rates of catheter-associated thrombosis and possible mechanical complications. The purpose of this review is to describe the complications after implantation of TIVAPs in the forearm, and to make radiologists familiar with the key findings of the complications during radiological imaging, including colour-coded and compression Duplex ultrasound, computed tomography, and digital subtraction venography.


Assuntos
Cateteres de Demora/efeitos adversos , Antebraço , Radiologia Intervencionista , Obstrução do Cateter/efeitos adversos , Falha de Equipamento , Antebraço/irrigação sanguínea , Humanos , Radiografia , Trombose/diagnóstico por imagem , Trombose/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA